November 19, 2026
Specifier Guide

How much open area does a perforated facade need?

Open area sets how much light, air and view a perforated panel lets through, and how strong it stays. The ranges we work to for facades, screens, pergolas and balustrades.

Curved corner of the Hertex perforated aluminium facade in Cape Town, made and installed by TILT

Open area is the share of a perforated panel that is cut away, given as a percentage. It is the single number that decides how a perforated facade behaves: how much light, air and view it lets through, how much sun and glare it stops, and how much metal is left to hold the panel together.

What changes as open area goes up

Illustrative render comparing perforated aluminium panels at 5, 20, 40 and 60 percent open area

Illustrative render of the same panel size at 5, 20, 40 and 60 percent open area.

  • Light and view: more open area passes more daylight and more of the view through the panel.
  • Air: more open area lets more air move through, which helps screened plant rooms, car parks and walkways.
  • Sun and glare: less open area stops more direct sun. Ratios can be set per elevation, so a west face can be tighter than a south face.
  • Strength: more open area leaves less metal, so the panel needs more support. That is why open area is capped on facades.
  • Privacy: less open area hides more, especially by day when it is brighter outside than in.

The ranges we work to

  • Facades and cladding: up to 40% open, which keeps the sheet strong and the face solid enough to read as a surface.
  • Screens: 12% to 55% open, enough see-through and airflow while the sheet holds its shape.
  • Pergolas and sunscreens: 25% open or more, so the pattern lets light and air through rather than blocking them.
  • Balustrade infill: small, even openings only, with no long slots or large voids.

Our perforation options run from about 5% to 60% open and more, in round, slot, square, hexagonal and custom laser-cut apertures. These ranges are a guide, not an engineering statement: balustrade heights, loads and apertures, and wind load on large facades, are always checked per project.

Pattern matters as much as the number

Two panels at the same open area can look very different. Small, even holes read as a texture. Long slots read as lines and let more of the view through in one direction. On the Hertex facade in Cape Town, a leaf pattern runs unbroken across the panel joints, so the facade reads as one screen. On The Rockefeller, slots of different lengths give the stair tower its texture and carry the building's name. See both in our Hertex and Rockefeller case studies.

Finish changes how open it looks

A dark finish makes a pattern recede and a light or metallic one pulls it forward, so the same open area can feel more or less solid. Look at a sample in your colour before you commit. Browse colours and finishes or request free samples.

Questions

Is open area measured across the whole panel?

On our patterns it is measured across the perforated field and excludes the solid border, so you can compare patterns on the same basis.

Can you change the open area of a pattern?

Often, yes. Hole size, spacing and the solid border can be adjusted within our CNC rules. Tell us what the facade needs to do and we will recommend a pattern and open area.

Read about our aluminium perforated panels, browse the pattern library, or try the facade simulator.